In my opinion Rpim is not related directly to anomalous signal, so perhaps that
is why there is some confusion.
Also I think some folks confused Rpim with Rrim. The latter is also called
Rmeas. But once again, these are not related directly to anomalous signal. I
do not find Rpim very useful
Joao,
I am using the latest version of phenix 1.8.1-1168
1.8.1-1168 should not have that "problem".
If you suspect there is still a problem, you can send me the data and model
files off list, explain what exactly the problem is, and I will have a look
right away.
FYI: there is Phenix mailing l
Hi,
I am using the latest version of phenix 1.8.1-1168 for the MacOSX and I
see a similar behaviour with the B-factors.
Which version do you suggest to update to?
There might be a problem with over-refinement and one workaround might be
to limit the Rfree-R=0.05, but your Rfree will likely to incr
That sounds like the bug in Phenix.refine v1.8 that a few of us encountered -
updating to the latest release will help.
Actually wasn't so much a bug but a "feature", albeit not the best one
imaginable. Anyone using older v1.8 versions should update.
---
Phil Jeffrey
Princeton
On Nov 2, 2012,
It could be a problem with your data, e.g. many overloaded reflections
not being removed or F and F^2 mixed up. What is your Wilson B-value?
George
--
Prof. George M. Sheldrick FRS
Dept. Structural Chemistry,
University of Goettingen,
Tammannstr. 4,
D37077 Goettingen, Germany
Tel. +49-551-39-30
Dear Tim,
this affects all atoms and yes I did reset the B-factors to 20.00 prior
to refinement. I have not tried REFMAC but now I will give it a try
since phenix does not seem to do the job.
best
Demetres
On 2/11/2012 1:34 μμ, Tim Gruene wrote:
-BEGIN PGP SIGNED MESSAGE-
Hash: SH
-BEGIN PGP SIGNED MESSAGE-
Hash: SHA1
Dear Demetres,
does this affect all atoms, or only a few selected ones?
Did you compare with refmac5 (for e.g. input script errors), or did
you reset the B-factors to a reasonable value (e.g. 20-30) prior to
refinement? pdbset can do this convenientl
Hello,
I am experiencing a weird problem with B factor refinement (individual,
isotropic) in phenix.refine (1.8.1.-1168) and a structure at 1.9 A
resolution. The ADP values after the refinement are very very low, less
than 2 and sometimes 0. I am getting the same result with and without
opti