OMG - thank you so much! I'd never have figured that out!
Thanks,
-John Elliott
*John Elliott*
Security Team Lead / Systems Administrator - A.I.S.
*C*alifornia *C*ollege of the *A*rts
Phone: 415.551.9228
Zoom Personal Meeting URL: https://cca.zoom.us/j/3677415794
technology.cca.edu | Email:
On Fri, Jan 23, 2015 at 4:17 PM, John Elliott wrote:
> Hi All,
> When I try to start bacula-director, I get the following error:
>
> # service bacula-director start
> * Starting Bacula Director...
> 23-Jan 13:14 bacula-dir: ERROR TERMINATION at parse_conf.c:976
> Config error: expected an equa
Hi All,
When I try to start bacula-director, I get the following error:
# service bacula-director start
* Starting Bacula Director...
23-Jan 13:14 bacula-dir: ERROR TERMINATION at parse_conf.c:976
Config error: expected an equals, got: {
: line 2, col 9 of file /etc/bacula/conf.d/fi
Hello,
2015-01-23 20:57 GMT+01:00 Dimitri Maziuk :
> On 01/23/2015 01:33 PM, Heitor Faria wrote:
>
> > Even though, IMHO, spooling disks backup is just "muda" (Japanese Term):
> http://en.wikipedia.org/wiki/Muda_(Japanese_term)
>
> so are proxies and caching: spool disk is just a variation on
>
On 01/23/2015 02:33 PM, Radosław Korzeniewski wrote:
> No, it is not working as you described.
> Data spooling will read stream from the client, then write it to the
> temporary disk file, then during despool it is stopping a stream from the
> client, reads a temporary file and write to destinatio
On 1/23/2015 2:33 PM, Heitor Faria wrote:
>> On 01/23/2015 12:22 PM, Radosław Korzeniewski wrote:
>>
>>> If you are using a vchanger then I guess it is a disk only backup, so why
>>> do you spool data? It is not required but making you backup slow down at
>>> least 2 times then standard job.
>> It
Hello,
2015-01-23 20:04 GMT+01:00 Dimitri Maziuk :
> On 01/23/2015 12:22 PM, Radosław Korzeniewski wrote:
>
> > If you are using a vchanger then I guess it is a disk only backup, so why
> > do you spool data? It is not required but making you backup slow down at
> > least 2 times then standard jo
> Even though, IMHO, spooling disks backup is just "muda" (Japanese
> Term): http://en.wikipedia.org/wiki/Muda_(Japanese_term)
Not necessarily - if you have a number of backups that tend to flake out
halfway through for whatever reasons (network, client issues, user
issues, etc) e.g. then by spoo
On 01/23/2015 01:33 PM, Heitor Faria wrote:
> Even though, IMHO, spooling disks backup is just "muda" (Japanese Term):
> http://en.wikipedia.org/wiki/Muda_(Japanese_term)
so are proxies and caching: spool disk is just a variation on
that theme.
--
Dimitri Maziuk
Programmer/sysadmin
BioMagResB
> On 01/23/2015 12:22 PM, Radosław Korzeniewski wrote:
>
> > If you are using a vchanger then I guess it is a disk only backup, so why
> > do you spool data? It is not required but making you backup slow down at
> > least 2 times then standard job.
>
> It's 2 times slower if your spool/despool is
On 01/23/2015 12:22 PM, Radosław Korzeniewski wrote:
> If you are using a vchanger then I guess it is a disk only backup, so why
> do you spool data? It is not required but making you backup slow down at
> least 2 times then standard job.
It's 2 times slower if your spool/despool is strictly sequ
Hello,
2015-01-22 3:42 GMT+01:00 Dimitri Maziuk :
> On 01/21/2015 06:41 PM, Bill Arlofski wrote:
>
> > Bacula has a hard-coded 6 day limit on a job's run time. 518401
> seconds =
> > 6.1157 days, so it appears that is the cause for the watchdog
> killing the job.
>
> Hard-coded, huh? Nobody
On 01/23/2015 09:57 AM, Josh Fisher wrote:
> ... Have you been able to determine what
> exactly is slow? I wonder if when the data spool file gets full it
> triggers a de-spool of both data and attributes, rather than just data?
Look like there's something wrong with the spool disk: I replaced it
Hello all,
The issue with Mantis bug tracker for Bacula-Web project is fixed now.
Feel free to sign up and add bug report and/or feature request.
Mantis Bug Tracker: http://bugs.bacula-web.org
Whish you an excellent week-end
Best regards
Davide
On Fri, Jan 23, 2015 at 9:10 AM, Davide Franco
On 1/23/2015 10:36 AM, Dmitri Maziuk wrote:
On 1/23/2015 9:03 AM, Josh Fisher wrote:
I use another approach. I define the vchanger to have multiple
virtual drives... So for 10 concurrent jobs there would be 10 virtual
drives and so 10 opened volume files.
My way also keeps the config simple s
On 1/23/2015 9:03 AM, Josh Fisher wrote:
> I use another approach. I define the vchanger to have multiple virtual
> drives... So for 10 concurrent jobs there would be 10 virtual
> drives and so 10 opened volume files.
My way also keeps the config simple stupid: as long as the backups
complete on
On 1/22/2015 1:30 PM, Damien Hull wrote:
I’ve asked this question before, but I don’t think I got enough
information. Here’s my situation
1.I have three offices in different physical locations.
2.Each location has between 200 GB to well over 1 TB of data.
3.I would like to backup data betw
On 1/22/2015 12:47 PM, Dimitri Maziuk wrote:
On 01/22/2015 10:07 AM, Josh Fisher wrote:
There is likely no reason to have SpoolData=yes for disk volumes, and it
could actually slow things down.
On 01/22/2015 07:32 AM, Clark, Patricia A. wrote:
Spooling is for the benefit of tape drives and
Just tripped over MHVTL - it may be of interest for test purposes possibly.
Seems to be tested with Bacula already.
*mhVTL*
"https://sites.google.com/site/linuxvtl2";
*MHVTL - virtuelle Tape Library*
"http://www.libe.net/index.php/MHVTL";
> Für Test oder Demozwecke kann mittels MHVTL eine oder m
Hi Uwe,
Thanks for your feedback, it's fully appreciated ...
In order to fix your problem, I'll need 3 things from you.
1. Your web server error logs
2. A screenshot of the buggy catalog selector
3. Your config.php file (don't forget to remove sensitive informations)
Best regards
Davi
Hello,
For those of you who encountered the same problem with Bacula-Web 7.0.1 or
7.0.2, I found a solution to fix it.
As of Bacula-Web version 7.0, the selected catalog_id is stored in the user
session. So if you modify the config.php and you remove the same catalog
that is used in the web ui.
S
On Thu, Jan 22, 2015 at 06:30:01PM +, Damien Hull wrote:
> I've asked this question before, but I don't think I got enough information.
> Here's my situation
>
> 1. I have three offices in different physical locations.
>
> 2. Each location has between 200 GB to well over 1 TB of da
On Thu, Jan 22, 2015 at 03:48:52PM +0100, Davide Franco wrote:
> Dear all,
>
> I'm really happy to announce that Bacula-Web version 7.0.2 is available from
> now.
>
> This "major bugfix / maintenance" release fixes 13 bugs (including 3 major
> bugs).
> I'd strongly suggest everyone to upgrade t
23 matches