Re: [Bacula-users] Bacula recognizes only 7 slots in an 8-slot-changer

2012-06-26 Thread Radosław Korzeniewski
Hello, 2012/6/26 Jens Gruentjes > boromir ~/tdtool # mtx -f /dev/sg4 status > RequestSense (0x03) failed > mtx: Request Sense: Long Report=yes > mtx: Request Sense: Valid Residual=no > mtx: Request Sense: Error Code=70 (Current) > mtx: Request Sense: Sense Key=Unit Attention > mtx: Request Sense

[Bacula-users] FileSet Question

2012-06-26 Thread Bryan Harris
Hello all, While running a job, if I look at the status of the client, bacula appears to be selecting files I don't want. If, say, I only want to backup "*.txt" files, the status makes it seem as though the server is backing up _all_ files. I'm using bacula 5.2.5 for both the client and serve

Re: [Bacula-users] Migration possible even with volume status "append"

2012-06-26 Thread Martin Simmons
> On Tue, 26 Jun 2012 15:01:30 +0200, Mario Moder said: > > As the subject says: I have a pool with a file storage and a migration > pool with a tape storage. The documentation says: "Volumes that are > still marked Append will not be considered for migration". > > I have a migration job wh

Re: [Bacula-users] Bacula Client Win 2008 64 bits don´t get a directory

2012-06-26 Thread John Drescher
> In Event Viewer I took a message: > > The Bacula File Service service is marked as an interactive service. > However, the system is configured to not allow interactive services. This > service may not work correctly. > That means bacula-fd.exe can not display a tray icon because windows now proh

[Bacula-users] setip not working

2012-06-26 Thread Gary Stainburn
I'm trying to get setip working and I'm struggling. I've set up a restricted console as described in the manual and it works for any other command, e.g. help, list. However, it doesn't work for setip. Can anyone help please. [bacula-dir.conf] Console { name = setIpConsole Password = "passwo

Re: [Bacula-users] Bacula recognizes only 7 slots in an 8-slot-changer

2012-06-26 Thread Jens Grüntjes
Zitat von "Gary R. Schmidt" : > Sorry, sent this direct, not to the list. > > On 26/06/2012 9:12 PM, Jens Grüntjes wrote: > [SNIP] >> Event Log - >> 00:00:51 Inventory Completed with OK status >> 00:00:51 Inventory, Element Id: 00F0h Cartridge: Yes, Barcode:

[Bacula-users] Migration possible even with volume status "append"

2012-06-26 Thread Mario Moder
Hi As the subject says: I have a pool with a file storage and a migration pool with a tape storage. The documentation says: "Volumes that are still marked Append will not be considered for migration". I have a migration job which does migrate from the appendable volume without an error. Could

Re: [Bacula-users] Building directory tree for JobId(s) for more than two days ...

2012-06-26 Thread Uwe Schuerkamp
On Fri, Jun 22, 2012 at 11:22:32AM -0400, Phil Stracchino wrote: > > That. Way too many people just run with the default config file that > the package installed. Or they go to the example configs and pick out > the "large server" configuration example and use that. > > The problem is, that "la

Re: [Bacula-users] Bacula recognizes only 7 slots in an 8-slot-changer

2012-06-26 Thread Gary R. Schmidt
Sorry, sent this direct, not to the list. On 26/06/2012 9:12 PM, Jens Grüntjes wrote: [SNIP] > Event Log - > 00:00:51 Inventory Completed with OK status > 00:00:51 Inventory, Element Id: 00F0h Cartridge: Yes, Barcode: WOC4-0 > 00:00:48 Inventory, Element Id:

Re: [Bacula-users] Bacula recognizes only 7 slots in an 8-slot-changer

2012-06-26 Thread Dan Langille
On 2012-06-26 07:12, Jens Grüntjes wrote: > Zitat von Marco van Wieringen : > >> Jens Grüntjes ebira.de> writes: >> >> Its something set in the changer. >> >> Check the tandberg web interface (guess the small 1u also has one) >> my 24 slots has one at least. >> >> Go to the Configure/Cleaning menu

Re: [Bacula-users] Bacula recognizes only 7 slots in an 8-slot-changer

2012-06-26 Thread Dan Langille
On 2012-06-26 01:38, Jens Gruentjes wrote: > Zitat von Dan Langille : > >> On 2012-06-25 10:30, Jens Grüntjes wrote: >> >> Make sure you have the latest and greatest mtx. >> >> I would start by debugging the output of this script. Look for >> these lines: >> >>list) >> debug "Doing mtx

Re: [Bacula-users] Bacula recognizes only 7 slots in an 8-slot-changer

2012-06-26 Thread Jens Grüntjes
Zitat von Marco van Wieringen : > Jens Grüntjes ebira.de> writes: > > Its something set in the changer. > > Check the tandberg web interface (guess the small 1u also has one) > my 24 slots has one at least. > > Go to the Configure/Cleaning menu and make sure Fixed Cleaning Slot Enabled: > is disa

Re: [Bacula-users] Reportula or bweb or webacula do not work anymore (Ubuntu 12.04)

2012-06-26 Thread Oliver Hoffmann
> > > webacula: > > > > PHP Fatal error: Uncaught exception 'Zend_Exception' with message > > 'Version error for Catalog database (wanted 12, got 14) ' > > in /var/www/webacula/html/index.php:183 Stack trace: #0 {main} > > thrown in /var/www/webacula/html/index.php on line 183 > Just change th