Hi PASA authors,
As requested in the 6lo WG meeting I’m relaying my comments on the smart home
use case (section 3.2 of draft-li-6lo-path-aware-semantic-addressing-00).
In Fig 2, it could be clarified better where the PASA Root sits (i.e. the root
and 6lo Border Router as depicted in the archit
Hi Esko,
Thanks for comments. In fact the second interpretation is closer. The Home
Gateway is the PASA root. However, the connection from the Home Gateway to the
PLC GWs is combination of Ethernet and PLC. More precisely, the Home Gateway
connects to a PLC GW (e.g. gwR) via Ethernet. Then this
Thanks David,
It would be nice to add some clarification for this, indeed. E.g. the Ethernet
link between Home Gateway and one PLC GW could be explicitly drawn. Now it’s
not so clear where the Home Gateway link is going (it interferes with the ASCII
art room boxes).
Also how the PLC network as
I assumed that the HomeRouter had a physical interface that was a PLC.
Maybe it's physically a USB cable, but the PLC's layer-3 interface was inside
the homerouter.
--
Michael Richardson. o O ( IPv6 IøT consulting )
Sandelman Software Works Inc, Ottawa and Worldwide
signatur