Hi David,

    When I looked into the ctapi.c code on the Reflex64 library, I have
noticed that
you are comparing cmd[0] to 0x20 but in a way which insets that value 0x20
to cmd[0],
i.e. if (cmd[0] = 0x20) and not if (cmd[0] == 0x20). This will put 0x20 as
the fist byte
of each command sent to the reader (dad = 1).

    I am using that last library from your site (Sep/98).

    Is this a BUG or am I missing something ?

    Looking forward to your reply.

    BTW: Is there a newer version for the Reflex64 ?


----- Original Message -----
From: David Corcoran <[EMAIL PROTECTED]>
To: <[EMAIL PROTECTED]>
Sent: Friday, October 08, 1999 2:35 PM
Subject: Re: MUSCLE Reflex 64


> Hi,
>
> In order to use the PIN entry on the Reflex 64 it is necessary to send the
> following byte stream
>
> 6b 00 15 10 08 00 03 01 04 02 0a 03 08 00 09 00 20 00 00 08 ff ff ff ff
>
> This could easily be added to the reflex 62/64's current CT-API with a
> series of IO_Writes beginning with an IO_Flush()
>
> Keep in mind though that this sends a Verify command directly to the card
> and not ALL cards use the same verify technique.
>
> Best Regards,
> Dave
>
> David Corcoran
> 1008 Cherry Lane
> West Lafayette, IN 47906
>
>
> ***************************************************************
> Linux Smart Card Developers - M.U.S.C.L.E.
> (Movement for the Use of Smart Cards in a Linux Environment)
> http://www.linuxnet.com/smartcard/index.html
> ***************************************************************
>

***************************************************************
Linux Smart Card Developers - M.U.S.C.L.E.
(Movement for the Use of Smart Cards in a Linux Environment)
http://www.linuxnet.com/smartcard/index.html
***************************************************************

Reply via email to