Dear David,
Thanks again for your help.
Why can't I use the CT_data command with the dad = 1 and sad = 2 ?
(I know for a fact that it doesn't work)
----- Original Message -----
From: David Corcoran <[EMAIL PROTECTED]>
To: <[EMAIL PROTECTED]>
Sent: Friday, October 08, 1999 2:35 PM
Subject: Re: MUSCLE Reflex 64
> Hi,
>
> In order to use the PIN entry on the Reflex 64 it is necessary to send the
> following byte stream
>
> 6b 00 15 10 08 00 03 01 04 02 0a 03 08 00 09 00 20 00 00 08 ff ff ff ff
>
> This could easily be added to the reflex 62/64's current CT-API with a
> series of IO_Writes beginning with an IO_Flush()
>
> Keep in mind though that this sends a Verify command directly to the card
> and not ALL cards use the same verify technique.
>
> Best Regards,
> Dave
>
> David Corcoran
> 1008 Cherry Lane
> West Lafayette, IN 47906
>
>
> ***************************************************************
> Linux Smart Card Developers - M.U.S.C.L.E.
> (Movement for the Use of Smart Cards in a Linux Environment)
> http://www.linuxnet.com/smartcard/index.html
> ***************************************************************
>
***************************************************************
Linux Smart Card Developers - M.U.S.C.L.E.
(Movement for the Use of Smart Cards in a Linux Environment)
http://www.linuxnet.com/smartcard/index.html
***************************************************************