On 10/27/05, Regin LARSEN <re...@opia.dk> wrote: > Cameron Harris skribis/wrote: > > Today, I checked out a CVS copy of the sane-backends, and compiled it > > all with genesys support. Unfortunately it hangs when i try scanimage > > you've to use the genesys-sources from the experimental directory > > > regin >
Well... I checked out experimental, copied the experimental/genesys/* over to the backend/ directory, then make clean/make/make install... Gets slightly further in the scanning this time. # SANE_DEBUG_GENESYS=255 scanimage -d genesys outputs lots of stuff and my scanner's head moves a little bit, flashes a few different colours.. but then it gets to... [genesys] sanei_genesys_read_data_from_scanner (size = 1560000 bytes) [genesys] genesys_read_valid_words [genesys] sanei_genesys_read_register (0x44, 0x00) completed [genesys] sanei_genesys_read_register (0x43, 0x00) completed [genesys] sanei_genesys_read_register (0x42, 0x00) completed [genesys] genesys_read_valid_words: 0 words [genesys] genesys_read_valid_words [genesys] sanei_genesys_read_register (0x44, 0x84) completed [genesys] sanei_genesys_read_register (0x43, 0x2b) completed [genesys] sanei_genesys_read_register (0x42, 0x00) completed [genesys] genesys_read_valid_words: 11140 words Where it stops for about 30 seconds, then... [genesys] sanei_genesys_read_data_from_scanner: reading bulk data failed: Error during device I/O [genesys] genesys_black_white_shading_calibration: Failed to read data: Error during device I/O [genesys] genesys_flatbed_calibration: failed to do dark+white shading calibration: Error during device I/O [genesys] genesys_start_scan: failed to do flatbed calibration: Error during device I/O scanimage: sane_start: Error during device I/O [genesys] sane_cancel: start Any ideas? Thanks :) -- Cameron Harris