Corey, Thanks for sharing this helpful information. I decided to test M190s on my shop in early 2010 before offering a new product. Until about 8 months ago, when we started seeing engineers specify Enphase, I refused to install more of the units. My breakdown in Midwest climes:
- M190 - 9/15 = 60% failure - M215 - 1/146 = 1% failure Matt Matthew Partymiller Solar Energy Solutions LLC (859) 312-7456 m...@solar-energy-solutions.com > I would be interested in hearing about other wrenches' observed Enphase > failure rates. > > Since 2010 we've installed 1347 total Enphase units with an overall > failure > rate of 3.27% > > Our breakdown is as follows: > > - M190 - 19/362 = 5.25% failed > - M210 - 21/545 = 3.85% failed > - D380 - 3/101 = 2.97% failed > - M215 - 1/339 = 0.29% failed > > -- > Corey Shalanski > Joule Energy > New Orleans, LA > _______________________________________________ > List sponsored by Home Power magazine > > List Address: RE-wrenches@lists.re-wrenches.org > > Change email address & settings: > http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org > > List-Archive: > http://lists.re-wrenches.org/pipermail/re-wrenches-re-wrenches.org > > List rules & etiquette: > www.re-wrenches.org/etiquette.htm > > Check out participant bios: > www.members.re-wrenches.org > > _______________________________________________ List sponsored by Home Power magazine List Address: RE-wrenches@lists.re-wrenches.org Change email address & settings: http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org List-Archive: http://lists.re-wrenches.org/pipermail/re-wrenches-re-wrenches.org List rules & etiquette: www.re-wrenches.org/etiquette.htm Check out participant bios: www.members.re-wrenches.org