I would be interested in hearing about other wrenches' observed Enphase failure rates.
Since 2010 we've installed 1347 total Enphase units with an overall failure rate of 3.27% Our breakdown is as follows: - M190 - 19/362 = 5.25% failed - M210 - 21/545 = 3.85% failed - D380 - 3/101 = 2.97% failed - M215 - 1/339 = 0.29% failed -- Corey Shalanski Joule Energy New Orleans, LA
_______________________________________________ List sponsored by Home Power magazine List Address: RE-wrenches@lists.re-wrenches.org Change email address & settings: http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org List-Archive: http://lists.re-wrenches.org/pipermail/re-wrenches-re-wrenches.org List rules & etiquette: www.re-wrenches.org/etiquette.htm Check out participant bios: www.members.re-wrenches.org