I would be interested in hearing about other wrenches' observed Enphase
failure rates.

Since 2010 we've installed 1347 total Enphase units with an overall failure
rate of 3.27%

Our breakdown is as follows:

   - M190 - 19/362 = 5.25% failed
   - M210 - 21/545 = 3.85% failed
   - D380 - 3/101 = 2.97% failed
   - M215 - 1/339 = 0.29% failed

--