Thanks Jay:
    That is true.  Enphase and Evergreen are not compatible.

 Nick Soleil
Project Manager
Advanced Alternative Energy Solutions, LLC
PO Box 657
Petaluma, CA 94953
Cell:   707-321-2937
Office: 707-789-9537
Fax:    707-769-9037




________________________________
From: jay peltz <j...@asis.com>
To: RE-wrenches <re-wrenches@lists.re-wrenches.org>
Sent: Wed, September 15, 2010 4:48:22 PM
Subject: Re: [RE-wrenches] GEC for Enphase inverters

Hi Nick,

Last time I checked Evergreen modules don't work with positive ground systems.

jay

peltz power

On Sep 15, 2010, at 9:19 AM, Nick Soleil wrote:

Yes, Enphase bonds the DC positive to ground in their inverters.  This allows 
them to work with all modules, including SunPower.
>