Rob
If your 5399 is setup for MMP, the only way a user can get two channels, is
if max_links = 2 or more

> -----Original Message-----
> From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]]On
> Behalf Of Rob Thomas
> Sent: Thursday, November 18, 1999 7:14 PM
> To: [EMAIL PROTECTED]; [EMAIL PROTECTED]
> Subject: [Bay-ISP] OK. Clues if anyone can..
>
>
> For the radiator guys: I'm using Radiator
> For the bay-isp guys: Well, you all know I'm a 5399 man 8-)
>
> After telling users for ages to bugger off, they can't have MPPP, I've
> got a customer who wants two 64K channels over ISDN.
>
> The question I'm asking is:
>
> In radiator, I've got:
>
> <Handler blah>
>   <Authby SQL>
>     Blah..
>   </AuthBy>
>   MaxSessions 1
> </Handler>
>
> Can I -override- the maxsessions by a responce back from SQL, or, will I
> need to set up a new handler for the mppp sessions?
>
> For the 5399 guys, I remember seeing a 'mp_max_sessions' or something
> like that somewhere.  Can that be over-ridden from radius, or will I
> need a new SPB?
>
> --Rob
> ---