Depending on the reason for ending the TB, we can chain to the next TB because the PC is constant.
Signed-off-by: Richard Henderson <richard.hender...@linaro.org> --- target/nios2/translate.c | 5 ++++- 1 file changed, 4 insertions(+), 1 deletion(-) diff --git a/target/nios2/translate.c b/target/nios2/translate.c index 51907586ab..6f31b6cc50 100644 --- a/target/nios2/translate.c +++ b/target/nios2/translate.c @@ -834,8 +834,11 @@ static void nios2_tr_tb_stop(DisasContextBase *dcbase, CPUState *cs) /* Indicate where the next block should start */ switch (dc->base.is_jmp) { case DISAS_TOO_MANY: + gen_goto_tb(dc, 0, dc->base.pc_next); + break; + case DISAS_UPDATE: - /* Save the current PC back into the CPU register */ + /* Save the current PC, and return to the main loop. */ tcg_gen_movi_tl(cpu_pc, dc->base.pc_next); tcg_gen_exit_tb(NULL, 0); break; -- 2.25.1