On 09/28/2011 09:01 PM, Blue Swirl wrote:
On Wed, Sep 28, 2011 at 11:00 AM, Jan Kiszka<jan.kis...@siemens.com>  wrote:
>  As we clearly modify the PIC state on pic_reset, we also have to update
>  the IRQ output. This only happened on init so far. Apply this
>  consistently.

Nack, IRQ lines shouldn't be touched on reset. The other side may not
be ready for receiving the interrupt change and qemu_irqs are
stateless anyway.


The way to fix it is two-phase reset:

phase 1: reset internal state (-> move all outputs to reset values), don't sample inputs yet
phase 2: allow sampling inputs



--
error compiling committee.c: too many arguments to function