When qemu dies from a signal, the python code gets a negative
value for exitcode; but signal numbers are positive.  Copy the
pattern used in qemu-iotests/iotests.py for reporting a positive
value.

CC: qemu-triv...@nongnu.org
Signed-off-by: Eric Blake <ebl...@redhat.com>
---
 scripts/qemu.py | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/scripts/qemu.py b/scripts/qemu.py
index 6e3b0e67719..0a5e02eb56e 100644
--- a/scripts/qemu.py
+++ b/scripts/qemu.py
@@ -351,7 +351,7 @@ class QEMUMachine(object):
                 command = ' '.join(self._qemu_full_args)
             else:
                 command = ''
-            LOG.warn(msg, exitcode, command)
+            LOG.warn(msg, -exitcode, command)

         self._launched = False

-- 
2.20.1