On Mon May 27, 2024 at 9:12 AM AEST, BALATON Zoltan wrote: > In ppc6xx_tlb_pte_check() the pp variable is used only once to pass it > to a function parameter with the same name. Remove the local and > inline the value. Also use named constant for the hex value to make it > clearer. >
Reviewed-by: Nicholas Piggin <npig...@gmail.com> > Signed-off-by: BALATON Zoltan <bala...@eik.bme.hu> > --- > target/ppc/mmu_common.c | 5 ++--- > 1 file changed, 2 insertions(+), 3 deletions(-) > > diff --git a/target/ppc/mmu_common.c b/target/ppc/mmu_common.c > index b21f52290f..799d2ced9b 100644 > --- a/target/ppc/mmu_common.c > +++ b/target/ppc/mmu_common.c > @@ -98,13 +98,12 @@ static int ppc6xx_tlb_pte_check(mmu_ctx_t *ctx, > target_ulong pte0, > target_ulong pte1, int pteh, > MMUAccessType access_type) > { > - int ret, pp; > + int ret; > > ret = -1; > /* Check validity and table match */ > if (pte_is_valid(pte0) && ((pte0 >> 6) & 1) == pteh) { > /* Check vsid & api */ > - pp = pte1 & 0x00000003; > if ((pte0 & PTE_PTEM_MASK) == ctx->ptem) { > if (ctx->raddr != (hwaddr)-1ULL) { > /* all matches should have equal RPN, WIMG & PP */ > @@ -115,7 +114,7 @@ static int ppc6xx_tlb_pte_check(mmu_ctx_t *ctx, > target_ulong pte0, > } > /* Keep the matching PTE information */ > ctx->raddr = pte1; > - ctx->prot = ppc_hash32_prot(ctx->key, pp, ctx->nx); > + ctx->prot = ppc_hash32_prot(ctx->key, pte1 & HPTE32_R_PP, > ctx->nx); > if (check_prot_access_type(ctx->prot, access_type)) { > /* Access granted */ > qemu_log_mask(CPU_LOG_MMU, "PTE access granted !\n");