On Thursday, May 21, 2020, postgann2020 s <postgann2...@gmail.com> wrote:

>
> SELECT seq_no+1 INTO pair_seq_no FROM SCHEMA.TABLE WHERE (Column1 like
> '%,sheath--'||cable_seq_id ||',%' or Column1 like 'sheath--'||cable_seq_id
> ||',%' or Column1 like '%,sheath--'||cable_seq_id  or
> Column1='sheath--'||cable_seq_id) order by seq_no desc limit 1 ;
>
>
> Could you please suggest a better way to execute the query
>

Add a trigger to the table to normalize the contents of column1 upon insert
and then rewrite your query to reference the newly created normalized
fields.

David J.

Reply via email to