On Friday, November 26, 2021 9:30 AM Masahiko Sawada <sawada.m...@gmail.com> 
wrote:
> 
> Indeed. Attached an updated patch. Thanks!

Thanks for your patch. A small comment:

+       OID of the relation that the worker is synchronizing; null for the
+       main apply worker

Should we modify it to "OID of the relation that the worker was synchronizing 
..."?

The rest of the patch LGTM.

Regards