On Tue, Nov 27, 2007 at 09:40:08AM -0800, Kok, Auke wrote: > > I'm afraid, I'm missing the point as you have stated that in-kernel drivers > > have problem with suspicious board hang... > > my mistake, sorry for that confusion. > > the fake hangs on 82562/6 devices occur on 10mbit link only. You can check in > the > code for a line that says: > > adapter->tx_timeout_factor = 8; > > change that number to 16 to cope with the problem on 10mbit link partners. > However this won't fix the issue on 100mbit partners and we need to > investigate that if that is the case.
100mbit is the issue in my case. -- Lukáš Hejtmánek - To unsubscribe from this list: send the line "unsubscribe netdev" in the body of a message to [EMAIL PROTECTED] More majordomo info at http://vger.kernel.org/majordomo-info.html