If the MII interface is used, the PHY is the clock master, thus don't
set the clock rate. On Zynq-7000, this will prevent the following
warning:
  macb e000b000.ethernet eth0: unable to generate target frequency: 25000000 Hz

Signed-off-by: Michael Walle <mich...@walle.cc>
---
 drivers/net/ethernet/cadence/macb_main.c | 4 ++++
 1 file changed, 4 insertions(+)

diff --git a/drivers/net/ethernet/cadence/macb_main.c 
b/drivers/net/ethernet/cadence/macb_main.c
index 814a5b10141d..472bf8f220bc 100644
--- a/drivers/net/ethernet/cadence/macb_main.c
+++ b/drivers/net/ethernet/cadence/macb_main.c
@@ -470,6 +470,10 @@ static void macb_set_tx_clk(struct macb *bp, int speed)
        if (!bp->tx_clk || (bp->caps & MACB_CAPS_CLK_HW_CHG))
                return;
 
+       /* In case of MII the PHY is the clock master */
+       if (bp->phy_interface == PHY_INTERFACE_MODE_MII)
+               return;
+