On Tue, Oct 20, 2020 at 12:12:32AM +0200, Andrew Lunn wrote: > > The auto-negotiation is a bit of a weird thing in this case, as there > > are two negotiations occurring, the 1000BaseX between the PCS/PMA PHY > > and the module PHY, and the 1000BaseT between the module PHY and the > > copper link partner. I believe the 88E1111 has some smarts to delay the > > copper negotiation until it gets the advertisement over 1000BaseX, uses > > those to figure out its advertisement, and then uses the copper link > > partner's response to determine the 1000BaseX response. > > But as far as i know you can only report duplex and pause over > 1000BaseX, not speed, since it is always 1G.
That is correct. -- RMK's Patch system: https://www.armlinux.org.uk/developer/patches/ FTTP is here! 40Mbps down 10Mbps up. Decent connectivity at last!