If the VF virtual link is set to always enabled, the speed may be unknown when the physical link is down. The driver currently logs the link speed as 4294967295 Mbps which is SPEED_UNKNOWN. Modify the link up log message as "speed unknown" which makes more sense.
Reviewed-by: Vasundhara Volam <vasundhara-v.vo...@broadcom.com> Reviewed-by: Edwin Peer <edwin.p...@broadcom.com> Signed-off-by: Michael Chan <michael.c...@broadcom.com> --- drivers/net/ethernet/broadcom/bnxt/bnxt.c | 6 +++++- 1 file changed, 5 insertions(+), 1 deletion(-) diff --git a/drivers/net/ethernet/broadcom/bnxt/bnxt.c b/drivers/net/ethernet/broadcom/bnxt/bnxt.c index ca35ec06abf0..2d6ecf1adbc5 100644 --- a/drivers/net/ethernet/broadcom/bnxt/bnxt.c +++ b/drivers/net/ethernet/broadcom/bnxt/bnxt.c @@ -8902,6 +8902,11 @@ static void bnxt_report_link(struct bnxt *bp) u16 fec; netif_carrier_on(bp->dev); + speed = bnxt_fw_to_ethtool_speed(bp->link_info.link_speed); + if (speed == SPEED_UNKNOWN) { + netdev_info(bp->dev, "NIC Link is Up, speed unknown\n"); + return; + } if (bp->link_info.duplex == BNXT_LINK_DUPLEX_FULL) duplex = "full"; else @@ -8914,7 +8919,6 @@ static void bnxt_report_link(struct bnxt *bp) flow_ctrl = "ON - receive"; else flow_ctrl = "none"; - speed = bnxt_fw_to_ethtool_speed(bp->link_info.link_speed); netdev_info(bp->dev, "NIC Link is Up, %u Mbps %s duplex, Flow control: %s\n", speed, duplex, flow_ctrl); if (bp->flags & BNXT_FLAG_EEE_CAP) -- 2.18.1
smime.p7s
Description: S/MIME Cryptographic Signature