> Could you please be a bit more specific about your setup?

Sure.

> Are you using pppoe(4) or pppoe(8)?

pppoe(4)

> Do you see maxed out mbufs (netstat -m), a very high interrupt load (top
> / vmstat -i), ifq drops (sysctl net.inet.ip.ifq.drops), interface errors
> (netstat -i)?

None of the above were maxed out on the P4.  It was only a quick test,
as this is the production spamd server.

> I'm running pppoe(4) on a lot of Geode 500MHz powered boxes and have no
> problem getting 30Mbit/s throughput of unencrypted traffic...

I plugged it back into the gw, Geode 300MHz with 100MBit Realtek.

I made the pf.conf as default as possible (to look like the
example pf.conf provided in /etc), I removed all the modulate and
synproxy state options that calomel suggested putting in pf.conf.

The performance improved from 1MB/s to 1.8MB/s.

I would love to get 3MB/s, but maybe 1.8MB/s is the limit of the
realtek NIC.

I have just ordered an Atom 1.8GHz with Gigabit Intel NICs, should
be more than good enough as an upgrade?  I may upgrade my link from
30Mbit to 100Mbit in future, I would expect the Atom to handle this.

.d.d.