From: Claudiu Beznea <claudiu.bez...@microchip.com> Date: Thu, 18 Jun 2020 11:37:40 +0300
> Undo previously done operation in case macb_phylink_connect() > fails. Since macb_reset_hw() is the 1st undo operation the > napi_exit label was renamed to reset_hw. > > Fixes: 7897b071ac3b ("net: macb: convert to phylink") > Signed-off-by: Claudiu Beznea <claudiu.bez...@microchip.com> Applied and queued up for -stable, thank you.