Add documentation about device operating mode and output data range
supported according to operating mode

Signed-off-by: Saravanan Sekar <[email protected]>
---
 .../ABI/testing/sysfs-bus-iio-wsen-itds       | 23 +++++++++++++++++++
 1 file changed, 23 insertions(+)
 create mode 100644 Documentation/ABI/testing/sysfs-bus-iio-wsen-itds

diff --git a/Documentation/ABI/testing/sysfs-bus-iio-wsen-itds 
b/Documentation/ABI/testing/sysfs-bus-iio-wsen-itds
new file mode 100644
index 000000000000..5979f2b8aa1a
--- /dev/null
+++ b/Documentation/ABI/testing/sysfs-bus-iio-wsen-itds
@@ -0,0 +1,23 @@
+What:          /sys/bus/iio/devices/iio\:device0/in_accel_samp_freq_available
+KernelVersion: 5.7
+Contact:       [email protected]
+Description:
+               Reading gives range of sample frequencies available for current 
operating mode
+               after one data has generated.
+
+               Access: Read
+               Valid values: represented in Hz
+               - range [12.5, 1600] for high permormance mode
+               - range [1.6, 200] for normal/low power mode
+
+What:          /sys/bus/iio/devices/iio\:device0/operating_mode
+KernelVersion: 5.7
+Contact:       [email protected]
+Description:
+               Represents the device operating mode. High performance mode 
gives high output
+               data rate and low noise compared to normal mode. Normal mode 
consumes less
+               current.  In single shot device enters to lowpower after one 
data has
+               generated.
+
+               Access: Read, Write
+               Valid values: "lowpower", "normal", "high_perf", "single_shot"
-- 