On Wed, Dec 6, 2017 at 1:30 PM, Stefan Agner <ste...@agner.ch> wrote:
> All Colibri iMX7 SKUs use either single-die NAND or eMMC, hence
> NAND_CE1 is not used on the module and can be used as a GPIO by
> carrier boards.
>
> Signed-off-by: Stefan Agner <ste...@agner.ch>

Reviewed-by: Fabio Estevam <fabio.este...@nxp.com>

Reply via email to