Signed-off-by: Hien Dang <hien.dang...@rvc.renesas.com>
Signed-off-by: Khiem Nguyen <khiem.nguyen...@rvc.renesas.com>
---
 .../bindings/thermal/rcar-gen3-thermal.txt         | 79 ++++++++++++++++++++++
 1 file changed, 79 insertions(+)
 create mode 100644 
Documentation/devicetree/bindings/thermal/rcar-gen3-thermal.txt

diff --git a/Documentation/devicetree/bindings/thermal/rcar-gen3-thermal.txt 
b/Documentation/devicetree/bindings/thermal/rcar-gen3-thermal.txt
new file mode 100644
index 0000000..ed6ce45
--- /dev/null
+++ b/Documentation/devicetree/bindings/thermal/rcar-gen3-thermal.txt
@@ -0,0 +1,79 @@
+* DT bindings for Renesas R-Car Gen3 Thermal Sensor driver
+
+Required properties:
+- compatible           : "renesas,thermal-<soctype>",
+                         Examples with soctypes are:
+                           - "renesas,thermal-r8a7795" (R-Car H3)
+                           - "renesas,thermal-r8a7796" (R-Car M3)
+                           - "renesas,rcar-gen3-thermal" as fallback
+- reg                  : Address range of the thermal registers.
+- clocks               : Must contain a reference to the functional clock.
+- #thermal-sensor-cells : Please see ./thermal.txt
+
+Option properties:
+
+- interrupts           : Use interrupt
+- power-domain         : Must contain a reference to the power domain. This 
property is
+                         mandatory if the thermal sensor instance is part of a 
controllable power
+                         domain.
+
+Example (non interrupt support):
+
+       tsc1: thermal@e6198000 {
+               compatible = "renesas,thermal-r8a7795",
+                       "renesas,rcar-gen3-thermal";
+               reg = <0 0xe6198000 0 0x5c>;
+               clocks = <&cpg CPG_MOD 522>;
+               power-domains = <&sysc R8A7795_PD_ALWAYS_ON>;
+               #thermal-sensor-cells = <0>;
+               status = "okay";
+       };
+
+       thermal-zones {
+               sensor_thermal1: sensor-thermal1 {
+                       polling-delay-passive = <250>;
+                       polling-delay = <1000>;
+
+                       /* sensor ID */
+                       thermal-sensors = <&tsc1>;
+
+                       trips {
+                               sensor1_crit: sensor1-crit {
+                                       temperature = <90000>;
+                                       hysteresis = <2000>;
+                                       type = "critical";
+                               };
+                       };
+               };
+       };
+
+Example (interrupt support):
+
+       tsc1: thermal@e6198000 {
+               compatible = "renesas,thermal-r8a7795",
+                       "renesas,rcar-gen3-thermal";
+               reg = <0 0xe6198000 0 0x5c>;
+               interrupts = <GIC_SPI 67 IRQ_TYPE_LEVEL_HIGH>;
+               clocks = <&cpg CPG_MOD 522>;
+               power-domains = <&sysc R8A7795_PD_ALWAYS_ON>;
+               #thermal-sensor-cells = <0>;
+               status = "okay";
+       };
+
+       thermal-zones {
+               sensor_thermal1: sensor-thermal1 {
+                       polling-delay-passive = <250>;
+                       polling-delay = <0>;
+
+                       /* sensor ID */
+                       thermal-sensors = <&tsc1>;
+
+                       trips {
+                               sensor1_crit: sensor1-crit {
+                                       temperature = <90000>;
+                                       hysteresis = <2000>;
+                                       type = "critical";
+                               };
+                       };
+               };
+       };
-- 