Using third party Strain Amplfiers, feeding DC output to NI 1102
multiplexer to increase channel count, has anyone a vi. already?

As I see required events, measure un-strained millivolt value, file,
after applying force, measure strained millivolt value, determine
difference between strained and unstrained, convert delta millivolts
to strain, and present.
Using NI strain gage boards is good, if we already had them.  They are
either 4 or 8 chan/board.  Amplifiers we already have along with
several NI 1102 multiplexed boards.  These allow us 32 strains/board.
Calibration can be done by using external shunt with calculated
equivalent strain, setting amplifier gain accordingly i.e., 1000ue=1.0
volts.
Can eventually arrive at working vi., but if someone has done this and
are willing to share, it would be of great benifit.  Time is always of
the essence.

Reply via email to