Hi,
I am rewiring after a hotel fire and need to get some info on cabling
thresholds.  The existing cable varies from CAT-nasty to Cat-5e,
Miscellaneous IDFs, 66-blocks, are scattered along the runs as well as
old crimps & splices.  Unfortunately there will not be enough money to
recable the whole place.
 
I set the clients up with an old 1232-11D and even though a run is
within 300 meters I cannot set up a system phone in one of the temporary
offices.  A standard T&R set works fine but the flash concept seems to
be beyond some of the girls there. . . . . .
 
What I'm looking for is a resistance reading on my meter that I can work
with and any info from someone that has traced out circuits using an
meter.  
 
Thanks for any Info.
 
Ray Martin,
Island Wide Communication.
Nantucket, MA 02554
 