On 5/12/2023 9:57 AM, dee david via KRnet wrote:
2. Why is the pressure not forcing the fuel to the primer
plunger? Laws of physics say it should be there.. right?
Any comments will be appreciated
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
Is the primer plumbed correctly, i.e., when you pull out on the primer
does it fill with fuel? Cut the system in half to troubleshoot. It has
to get fuel before it can dispense fuel. It sounds like you expect fuel
to be at the primer inlet from gravity when you pull out the plunger.
Remove that connection and verify. If not, work backwards. That system
is a basic system like a series circuit in electronics. If it is not
working at some point work backwards till you find where it is working
then identify and fix the problem.
This is all a "guess" on my part.
Larry Flesner
--
KRnet mailing list
KRnet@list.krnet.org