Well,
  I guess I should have prefaced my post with:
"I was thinking about grounding my wing attach fittings."
The idea was to run braid to the FWD fittings only so
it would serve as a ground point.  Then I don't have to
run a third wire all the way back from wingtip lights
fueltank etc to the firewall as any connection could
pick up ground at the attach fitting.
   The main reason I had the idea as there was a bolt
hole there already, and it's easy to add a star washer
and a couple of wires.  I should have also added that
you probably want a seperate wire to connect the outer and
inner fittings together, as if you rely on the bolts to
give you good contact, you could have problems... i.e.
radio noise, bad connections, hard to track down etc etc.

   That was when I was concerned about having a ground
path for the fuel tanks to prevent static buildup.  I'm
relying on my grounded fuel sender to do this now.

  So, simply grounding the wing attach fittings is
not a great idea in itself, but if you want to use the
wing attach fitting on the removable wing as a ground point, it's an idea.

-- Ross
----- Original Message -----
From: "Ron Freiberger" <rfreiber...@swfla.rr.com>
List-Post: krnet@list.krnet.org
Date: Tue, 23 Sep 2003 19:13:07 -0500
To: "KR builders and pilots" <kr...@mylist.net>
Subject: RE: KR>Ground / Earth Wiring/ Stall Warning

> Ross said,
> I would recommend
> running a 1/4" ground unshielded braid aft to the elev horn
> mount, and mount it there.  I would also consider running a 
> braid to the wing attach fittings, but I haven't done that.
> 
> What possible electrical reason would you have for doing that?
> 
> Ron Freiberger
> mailto: rfreiber...@swfla.rr.com
> 
>  
> 
> 