Paul Visk wrote:

 >>Did the switch fail because it was undersized for a DC circuit?

I don't think so.  It's supposed to be rated for 10A, and I was only 
pulling 5.1A through it, and one just like it (bought at the same time 
from AS&S) powered the same system on N56ML for all that time with zero 
problems.  I think it was infant mortality...it literally rattles now, 
as if a contact broke completely loose inside.  I borrowed the one from 
N56ML for now, but will install a 30A DC version shortly.  I flew it 
almost every day last week, and the only reason I quit after only a half 
hour today is because it started hailing on me...

Mark Langford
ML at N56ML.com
http://www.n56ml.com