Volume &SYSR1. and volume ****** are equivalent.  HLQ &SYSR1.. is a whole 
different matter.

i.e.
DEF NVSAM(NAME(datasetname) DEVT(3390) VOL(&SYSR1.))
and
DEF NVSAM(NAME(datasetname) DEVT(3390) VOL(******))

Should resolve identically.
The "advantage of &SYSR1 is that it is easily extensible to &SYSR2,.......

HTH,


-----Original Message-----
From: IBM Mainframe Discussion List <IBM-MAIN@LISTSERV.UA.EDU> On Behalf Of 
Barbara Nitz
Sent: Tuesday, August 27, 2019 11:52 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: Clarification on DASD mod conversion of SYSRES

>There shouldn’t be Jake.  I'm running MOD-54's for my sysres volumes and have 
>been for years.   Probably the only issue you might have is if you are going 
>from a multi-sysres config where you had multiple system symbols for catalog 
>purposes, you'll just have to fix that to all use either ****** or &SYSR1.

The last time I did this exercise (when rearranging an ADCD system) about 4-5 
years ago I fell flat on my face when I catalogued the sysres data sets on the 
sysres I IPL'd from to use the qualifier &SYSR1.. The system didn't come up 
because it found just about nothing. After staring at the manual for a while, I 
read the manual that you *must* use ****** for all data sets on the sysres 
volume you use to IPL. Sure enough, once I had recatalogued everything from 
&SYSR1. to ******, the system came up.

Has that changed in the meantime? Are &SYSR1. and ****** interchangeable?

Regards, Barbara

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
lists...@listserv.ua.edu with the message: INFO IBM-MAIN
::DISCLAIMER::
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
The contents of this e-mail and any attachment(s) are confidential and intended 
for the named recipient(s) only. E-mail transmission is not guaranteed to be 
secure or error-free as information could be intercepted, corrupted, lost, 
destroyed, arrive late or incomplete, or may contain viruses in transmission. 
The e mail and its contents (with or without referred errors) shall therefore 
not attach any liability on the originator or HCL or its affiliates. Views or 
opinions, if any, presented in this email are solely those of the author and 
may not necessarily reflect the views or opinions of HCL or its affiliates. Any 
form of reproduction, dissemination, copying, disclosure, modification, 
distribution and / or publication of this message without the prior written 
consent of authorized representative of HCL is strictly prohibited. If you have 
received this email in error please delete it and notify the sender 
immediately. Before opening any email and/or attachments, please check them for 
viruses and other defects.
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to