On Wed, May 22, 2019 at 9:46 AM Tom Marchant < [email protected]> wrote:
> On Tue, 21 May 2019 22:03:35 -0400, Tony Thigpen wrote: > > >Some sandbox testing shows that IEFSSN00 *seems to be* starting all > >subsystems that: > >1) Contain the INITRTN() verb, and, > >2) Have a proc in SYS1.PROCLIB with the same name as the SUBNAME() verb. > > > >So, on the system containing the IEFSSN00 shown below, SMS, JES2, RACF > >and IXFP are started. DFRM is not started because our RMM proc in > >SYS1.PROCLIB has a different name. > > > >Of course, this could all be just a coincidence and I am still missing > >something. :-) > > Have you looked at the System Initialization section in the Initialization > and > Tuning Guide? > > https://www.ibm.com/support/knowledgecenter/SSLTBW_2.3.0/com.ibm.zos.v2r3.ieae100/initprc.htm That's a new one on me. Thanks for the URL. > > > -- > Tom Marchant > -- This is clearly another case of too many mad scientists, and not enough hunchbacks. Maranatha! <>< John McKown ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN
