Friday reverie. I remember when and why we inserted CLPA into IEASYSxx. Mid 1980s. Up to that time disk was considered to be 'slow enough' as to relegate CLPA to specific situations where 'we' (mighty all-knowing sysprogs) knew that LPA had changed in some way since the previous IPL. One day we had a system crash with no operators around. We had to roll up our sleeves and save the day. The chalk board on the wall told us which sysres volume to IPL from. Since it was a simple down-and-up situation, no CLPA was needed.
We began getting the weirdest abend reports. We experienced them ourselves. After much consternation, we determined that we had IPLed from the wrong sysres. Chalk board was wrong. Without CLPA, we were mixing down-level link list with newer LPA list. Random mismatches, random kabooms. We reIPLed the correct way, all better. At the next Change Control meeting, we announced that from then on every IPL would be CLPA. Skepticism abounded but did prevail. I don't think anyone ever actually perceived a difference in IPL time. For sure we never had another LINK/LPA mismatch. . . J.O.Skip Robinson Southern California Edison Company Electric Dragon Team Paddler SHARE MVS Program Co-Manager 323-715-0595 Mobile 626-543-6132 Office ⇐=== NEW [email protected] -----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of Gibney, Dave Sent: Friday, August 24, 2018 2:31 PM To: [email protected] Subject: (External):Re: 0,clpa What Skip says.... Disk hasn't been slow enough to keep the LPA for a long, long time... > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:[email protected]] > On Behalf Of Jesse 1 Robinson > Sent: Friday, August 24, 2018 2:24 PM > To: [email protected] > Subject: Re: 0,clpa > > CLPA in IEASYSxx is the answer. Been that way for decades. Long before > aich em cee. This is apart from any other operator prompting that > might be requested or allowed. > > . > . > J.O.Skip Robinson > Southern California Edison Company > Electric Dragon Team Paddler > SHARE MVS Program Co-Manager > 323-715-0595 Mobile > 626-543-6132 Office ⇐=== NEW > [email protected] > > > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:[email protected]] > On Behalf Of Allan Staller > Sent: Friday, August 24, 2018 2:04 PM > To: [email protected] > Subject: (External):Re: 0,clpa > > 1) as one other poster inidicated, add clap to IEASYS00 > 2) Check your load parms on the hmc. In the SYSPARMS parameter > ddddyyzz yy has significance as does zz. They may/may not request a > prompt depending on the value. > > MVS SYSTEM COMMANDS (?) has the breakdown. I believe much of the same > info is duplicated in Init and Tuning. > > HTH, > > -----Original Message----- > From: IBM Mainframe Discussion List <[email protected]> On > Behalf Of Tony Thigpen > Sent: 24 August 2018 15:01 > To: [email protected] > Subject: 0,clpa > > Every time one specific z/os system IPLs, I have to enter: > 0,clpa > on the console to get it to continue. I have other machines that do > not prompt. What can I set to avoid having to enter this response during ipl? > -- > Tony Thigpen ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN