I have seen this happen with an extreme mismatch in LPAR weights.
Check your MASDEF parameters.

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of Salah Balboul
Sent: Thursday, April 19, 2018 9:48 AM
To: [email protected]
Subject: SYSPLEX Hung

Hi,

For the past week we've had 2 crashes due to one LPAR being hung in a two 
SYSPLEX LPAR causing sympathy sickness.

In both cases the indication is $HASP263 message (Checkpoint lock), followed by 
*MASTER* pending on the JES2 CKPT volume.

Finally IXC426D to partition the sick LPAR out.

We do not have an SFM policy in effect, no changes done or maintenance applied.

The problem LPAR SYSLOG stops recording approx 10-12 prior to IXC426D message. 
NO indication of any issues on problem LPAR.

I wonder if anyone has seen this.

I don't think JES2 is causing this, it is a victim.

Thoughts?

Thanks

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN
::DISCLAIMER::
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
The contents of this e-mail and any attachment(s) are confidential and intended 
for the named recipient(s) only. E-mail transmission is not guaranteed to be 
secure or error-free as information could be intercepted, corrupted, lost, 
destroyed, arrive late or incomplete, or may contain viruses in transmission. 
The e mail and its contents (with or without referred errors) shall therefore 
not attach any liability on the originator or HCL or its affiliates. Views or 
opinions, if any, presented in this email are solely those of the author and 
may not necessarily reflect the views or opinions of HCL or its affiliates. Any 
form of reproduction, dissemination, copying, disclosure, modification, 
distribution and / or publication of this message without the prior written 
consent of authorized representative of HCL is strictly prohibited. If you have 
received this email in error please delete it and notify the sender 
immediately. Before opening any email and/or attachments, please check them for 
viruses and other defects.
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to