Greedy aren't you .....
Chris Hoelscher Technology Architect, Database Infrastructure Services Technology Solution Services 123 East Main Street Louisville, KY 40202 Humana.com (502) 476-2538 or 407-7266 -----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of Adams, Anne (DTI) Sent: Tuesday, August 29, 2017 12:13 PM To: [email protected] Subject: Re: [IBM-MAIN] SMFLIMxx parameter Hey Carmen! Yep, and things still don't work. However, if I change REGIONABOVE to 2G (or whatever I have in SMFPRMxx) then It works just fine ... except for the fact that the region size is only 2G ... and I want it all. Anne R. Adams, CISSP DTI, Systems Engineering Sr. Mainframe Services Analyst 302.298.3196 -----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of Carmen Vitullo Sent: Tuesday, August 29, 2017 11:57 AM To: [email protected] Subject: Re: SMFLIMxx parameter Hi Anne, tell Everyone I said YO! all the example I've seen show REGION JOBNAME(*) SUBSYS(JES*,STC) REGIONABOVE(NOLIMIT) REGIONBELOW(NOLIMIT) SYSRESVABOVE(50M) SYSRESVBELOW(512K) looks like the error is pointing to the SYSRESVBELOW posssibly did you try reversing the order and try again? Carmen ----- Original Message ----- From: "Anne Adams (DTI)" <[email protected]> To: [email protected] Sent: Tuesday, August 29, 2017 10:47:04 AM Subject: Re: SMFLIMxx parameter Hey Steve - Here's how we set up SMFLIMxx REGION JOBNAME(*) SUBSYS(STC,JES2) REGIONABOVE(NOLIMIT) REGIONBELOW(NOLIMIT) SYSRESVBELOW(512K) SYSRESVABOVE(100M) MEMLIMIT(10P) If we left SMFPRMxx MEMLIMIT(2G) then the maximum region size remained, 2G. Likewise if we put 4G or 6G that was the maximum. However if we put NOLIMIT, then it appeared to default to 2G. We tried setting REGIONABOVE(4G) in SMFLIMxx and would get and error. T SMFLIM=00 IEE252I MEMBER SMFLIM00 FOUND IN SYS1.PARMLIB ASA008I ERROR IN PARMLIB MEMBER=SMFLIM00 ON LINE 3, POSITION 14: 362 VALUE IS NOT VALID - OUT OF RANGE. What I want to have happen is when we put NOLIMIT, the default is however much memory I have installed. Maybe I don't fully understand how this works. Anne R. Adams, CISSP DTI, Systems Engineering Sr. Mainframe Services Analyst 302.298.3196 -----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of Steve Sent: Friday, August 18, 2017 9:20 AM To: [email protected] Subject: Re: SMFLIMxx parameter Do you have the IEF043I joblog message and the SMFLIMxx rules that you could post? Along with whatever messages you get for the refusal to run... - Steve On 8/17/2017 1:03 PM, Adams, Anne , DTI wrote: > Hello Friends, > > Has anyone had any success using (or diagnosing failures) when using the > SMFLIMxx parameter? We have a few CICS and database regions and one > unrepentant job that refuse to run. > > Anne R. Adams, CISSP > DTI, Systems Engineering > Sr. Mainframe Services Analyst > 302.298.3196 > > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, send > email to [email protected] with the message: INFO IBM-MAIN > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN The information transmitted is intended only for the person or entity to which it is addressed and may contain CONFIDENTIAL material. If you receive this material/information in error, please contact the sender and delete or destroy the material/information. Humana Inc. and its subsidiaries comply with applicable Federal civil rights laws and do not discriminate on the basis of race, color, national origin, age, disability or sex. Humana Inc. and its subsidiaries do not exclude people or treat them differently because of race, color, national origin, age, disability or sex. English: ATTENTION: If you do not speak English, language assistance services, free of charge, are available to you. Call 1‐877‐320‐1235 (TTY: 711). Español (Spanish): ATENCIÓN: Si habla español, tiene a su disposición servicios gratuitos de asistencia lingüística. Llame al 1‐877‐320‐1235 (TTY: 711). 繁體中文(Chinese):注意:如果您使用繁體中文,您可以免費獲得語言援助 服務。請致電 1‐877‐320‐1235 (TTY: 711)。 Kreyòl Ayisyen (Haitian Creole): ATANSION: Si w pale Kreyòl Ayisyen, gen sèvis èd pou lang ki disponib gratis pou ou. Rele 1‐877‐320‐1235 (TTY: 711). Polski (Polish): UWAGA: Jeżeli mówisz po polsku, możesz skorzystać z bezpłatnej pomocy językowej. Zadzwoń pod numer 1‐877‐320‐1235 (TTY: 711). 한국어 (Korean): 주의: 한국어를 사용하시는 경우, 언어 지원 서비스를 무료로 이용하실 수 있습니다. 1‐877‐320‐1235 (TTY: 711)번으로 전화해 주십시오. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN
