AFAIK, the DATACLAS cannot be altered(nothing to do w/ZFS). The dataset must be 
copied.
dfDSS logical copy will work just fine. Other methods of your choice.

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of Jesse 1 Robinson
Sent: Wednesday, February 22, 2017 3:46 PM
To: [email protected]
Subject: Extended ZFS

Hope this does not smack of too lazy to wade through doc. We have a ZFS that 
has hit the 4GB limit. We want to 'transform' it to extended format. One 
opinion on the floor is that we could just ALTER the DATACLAS of the existing 
ZFS and let it expand on its own; the other opinion (mine) is that we have to 
create a new ZFS with the extended attribute and copy data from old to new. 
Who's right?

.
.
J.O.Skip Robinson
Southern California Edison Company
Electric Dragon Team Paddler
SHARE MVS Program Co-Manager
323-715-0595 Mobile
626-543-6132 Office <===== NEW
[email protected]<mailto:[email protected]>


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN


::DISCLAIMER::
----------------------------------------------------------------------------------------------------------------------------------------------------

The contents of this e-mail and any attachment(s) are confidential and intended 
for the named recipient(s) only.
E-mail transmission is not guaranteed to be secure or error-free as information 
could be intercepted, corrupted,
lost, destroyed, arrive late or incomplete, or may contain viruses in 
transmission. The e mail and its contents
(with or without referred errors) shall therefore not attach any liability on 
the originator or HCL or its affiliates.
Views or opinions, if any, presented in this email are solely those of the 
author and may not necessarily reflect the
views or opinions of HCL or its affiliates. Any form of reproduction, 
dissemination, copying, disclosure, modification,
distribution and / or publication of this message without the prior written 
consent of authorized representative of
HCL is strictly prohibited. If you have received this email in error please 
delete it and notify the sender immediately.
Before opening any email and/or attachments, please check them for viruses and 
other defects.

----------------------------------------------------------------------------------------------------------------------------------------------------

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to