So you could try to cheat.

HSM Migrate/RECALL with an updated  DATA Class.  

DATACLAS is only valid when the dataset is created.  So you cannot assign EA/EF 
without a DEL/DEF function (yes there are other elements that can be altered in 
the DATACLAS and be effective.  EA/EF is not one of them).

Or create a  new ZFS, copy old ZFS to new ZFS.  Use new ZFS

Lizette


> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[email protected]] On
> Behalf Of Mike Schwab
> Sent: Wednesday, February 22, 2017 3:05 PM
> To: [email protected]
> Subject: Re: Extended ZFS
> 
> https://www.ibm.com/support/knowledgecenter/en/SSLTBW_2.1.0/com.ibm.zos.v2r1.i
> oea700/ioea7d0041003067.htm
> 
> Must be CREATED Extended Format, Extended Addressabilty to grow bigger than
> 4GB.
> 
> On Wed, Feb 22, 2017 at 3:46 PM, Jesse 1 Robinson <[email protected]>
> wrote:
> > Hope this does not smack of too lazy to wade through doc. We have a ZFS that
> has hit the 4GB limit. We want to 'transform' it to extended format. One
> opinion on the floor is that we could just ALTER the DATACLAS of the existing
> ZFS and let it expand on its own; the other opinion (mine) is that we have to
> create a new ZFS with the extended attribute and copy data from old to new.
> Who's right?
> >
> > .
> > .
> > J.O.Skip Robinson
> > Southern California Edison Company
> > Electric Dragon Team Paddler
> > SHARE MVS Program Co-Manager
> > 323-715-0595 Mobile
> > 626-543-6132 Office <===== NEW
> > [email protected]<mailto:[email protected]>
> >
> > 
> 
> --
> Mike A Schwab, Springfield IL USA
> Where do Forest Rangers go to get away from it all?
> 

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to