Are you sure you are wanting CBU and not OOCoD? CBU is usually valid for 10 day 
test periods at a time for D/R tests before it becomes 'real'. For OOCoD, we 
make use of Capacity Provisioning Manager (which is part of zOS base) and then 
use our automation product to issue Capacity Provisioning Manager commands to 
change up/down our capacity markers. By using a combination of automation and 
CPM, you could accomplish what you want without much difficulty.

Roger 

On Mon, 27 Jun 2016 10:45:24 -0500, Robert McElhaney 
<robert.mcelha...@atos.net> wrote:

>I want to investigate CBU turn up for 2964-502 to 2964-407. I may want to do 
>this nightly. My central concern for this activity is HMC. I do not want to 
>have an operator each night having to modify HMC configuration manually each 
>night. I need a push button solution to HMC configuration for this specific 
>CBU turn up and subsequent turn down. Do we have anyone on this list with 
>exposure to this CBU option? BTW this is not for disaster recovery exercise. 
>This would be a steady state activity.
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN