Sure! Can you drop them by Marcello 4406 around 8am?

Sent from my Android phone using TouchDown (www.nitrodesk.com)

-----Original Message-----
From: Dave Barry [[email protected]]
Received: Tuesday, 05 May 2015, 3:54PM
To: [email protected] [[email protected]]
Subject: Re: IEFBR14 question

Some third-party software in use here at UPS has used this technique for years. 
 The assumption is perfectly valid.

Think about it:  If an initiator allocates a migrated dataset specifically on 
behalf of IEFBR14 -- which cannot even open it, much less use it -- just to 
process a normal disposition of DELETE, why waste HSM resources and tie up the 
initiator while waiting for the recall to complete?  The O/S might just as well 
schedule an HDELETE and be done with it.

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of Paul Gilmartin
Sent: Tuesday, May 05, 2015 12:25 PM
To: [email protected]
Subject: Re: IEFBR14 question

On 2015-05-05, at 10:16, Greg Shirey wrote:

> The O/S may never "use" the data set after the step runs, but perhaps "using" 
> the data set wasn't the point of running the step.   I'd prefer the O/S not 
> make that assumption for me.
>
And yet, lately, the O/S makes such an assumption when the data set is 
migrated.  Yes, as R.S. says, you can turn it off.
It should be possible to override it within a particular job, not system-wide.  
OS/360 was not designed as a multi-user system.  Its descendants inherit that 
original sin.

-- gil

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 