Also look at /*ROUTE statement in JES2  


Lizette

> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[email protected]] On
> Behalf Of Hardee, Chuck
> Sent: Tuesday, November 11, 2014 6:55 AM
> To: [email protected]
> Subject: Re: SMP/E APPLY output capture question
> 
> Thanks for the thought Lizette, but I did go down that path, but I found
no way to
> specify the OUTPUT= parameter in the SYSPRINT DDDEF.
> 
> Do you have an idea of how I would accomplish that?
> 
> C-
> 
> Charles (Chuck) Hardee
> Senior Systems Engineer/Database Administration EAS Information Technology
> 
> Thermo Fisher Scientific
> 300 Industry Drive | Pittsburgh, PA 15275 Phone +1 (724) 517-2633 | Mobile
+1
> (412) 877-2809 | FAX: +1 (412) 490-9230 [email protected] |
> www.thermofisher.com
> 
> WORLDWIDE CONFIDENTIALITY NOTE: Dissemination, distribution or copying of
> this e-mail or the information herein by anyone other than the intended
recipient, or
> an employee or agent of a system responsible for delivering the message to
the
> intended recipient, is prohibited. If you are not the intended recipient,
please inform
> the sender and delete all copies.
> 
> 
> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[email protected]] On
> Behalf Of Lizette Koehler
> Sent: Tuesday, November 11, 2014 8:48 AM
> To: [email protected]
> Subject: Re: SMP/E APPLY output capture question
> 
> See if the /*OUTPUT Jcl statement could help.
> 
> Lizette
> 
> 
> > -----Original Message-----
> > From: IBM Mainframe Discussion List [mailto:[email protected]]
> > On Behalf Of Hardee, Chuck
> > Sent: Tuesday, November 11, 2014 6:35 AM
> > To: [email protected]
> > Subject: Re: SMP/E APPLY output capture question
> >
> > Thanks Christian, but I tried that already.
> > I changed the utility to use the DD name ASMPRINT and then coded an
> > ASMPRINT DD with SYSYOUT=* and when the APPLY was executed I received
> > nothing via that DD, the usermod was not applied and I received no
> > errors
> indicating
> > that there was a problem with the assembly or a problem in the APPLY.
> > Very misleading.
> >
> > I will, however, try it again since you have indicated that it should
> work.
> > It is quite possible I did not have something quite right.
> >
> > I'll update again when I have further news.
> >
> > C-
> >
> > Charles (Chuck) Hardee
> > Senior Systems Engineer/Database Administration EAS Information
> > Technology
> >
> > Thermo Fisher Scientific
> > 300 Industry Drive | Pittsburgh, PA 15275 Phone +1 (724) 517-2633 |
> > Mobile
> +1
> > (412) 877-2809 | FAX: +1 (412) 490-9230 [email protected]
> > | www.thermofisher.com
> >
> > WORLDWIDE CONFIDENTIALITY NOTE: Dissemination, distribution or copying
> > of this e-mail or the information herein by anyone other than the
> > intended
> recipient, or
> > an employee or agent of a system responsible for delivering the
> > message to
> the
> > intended recipient, is prohibited. If you are not the intended
> > recipient,
> please inform
> > the sender and delete all copies.
> >
> > -----Original Message-----
> > From: IBM Mainframe Discussion List [mailto:[email protected]]
> > On Behalf Of Christian Birr
> > Sent: Tuesday, November 11, 2014 8:27 AM
> > To: [email protected]
> > Subject: AW: SMP/E APPLY output capture question
> >
> > Chuck,
> > in the SMP/E dialog select the global zone, under UTILITY select
> > ASMA90
> (or what
> > else you might use), specify a print DD name and use this in your JCL
> > and
> review
> > the PARM statements.
> > Christian
> > -----Ursprüngliche Nachricht-----
> > Von: IBM Mainframe Discussion List [mailto:[email protected]]
> > Im Auftrag von Hardee, Chuck
> > Gesendet: Dienstag, 11. November 2014 13:54
> > An: [email protected]
> > Betreff: SMP/E APPLY output capture question
> >
> > Hello Listers,
> >
> > I am in need of capturing the output from an APPLY step, specifically
> > the
> assembly
> > and link output.
> > Currently my target zone has SYSPRINT defined as SYSOUT=*.
> > I have tried several things but, unless I've coded them incorrectly,
> > they
> did not
> > achieve the result I need.
> >
> > I have tried supplying a defining a OUTPUT statement at the start of
> > my
> job and
> > then supplying a SYSPRINT DD with an OUTPUT= naming the OUTPUT
> > statement's name. That didn't work, and I didn't get any indication
> > from
> SMP/E as to
> > errors, but my usermod was not applied.
> >
> > I have tried defining the assembler utility as using an alternate
> > SYSPRINT
> DD and
> > then supplying that DD and I don't get the assembly output via the new
> > DD
> name
> > which I supplied in the JCL. In fact, I don't get any errors with that
> setup either but
> > the usermod did not apply in the arrangement either.
> >
> > Ultimately, what I want to accomplish it to have 2 copies of the output.
> One to go to
> > our production control department as part of the documentation filed
> > when
> locking
> > down the source and the other to stay within our own library system so
> that if we
> > have issues with the program being controlled, we have quicker and
> > easier
> access
> > to the current listing than we would if we had to go thru the
> > production
> control library.
> >
> > I can obtain the result I want, to a degree, if I manually change the
> output class,
> > form and destination as we have JES writers to handle it, but I'd
> > rather
> not have to
> > remember to go and change the various JES attributes of the job if I
> > can
> do it in the
> > JCL.
> >
> > If there is some way to cause SMP/E to spool its assembly and link
> > steps
> to VIO
> > that would be great as I could then follow the APPLY step with an
> > IEBGENER
> and
> > code SYSUT2 with the appropriate OUTPUT names and have the output
> > handled as I want.
> >
> > Anyone have any ideas?
> >
> > Thanks,
> > Chuck
> >
> > Charles (Chuck) Hardee
> > Senior Systems Engineer/Database Administration EAS Information
> > Technology
> >
> > Thermo Fisher Scientific
> > 300 Industry Drive | Pittsburgh, PA 15275 Phone +1 (724) 517-2633 |
> > Mobile
> +1
> > (412) 877-2809 | FAX: +1 (412) 490-9230 [email protected]
> > | www.thermofisher.com

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to