See if the /*OUTPUT Jcl statement could help.

Lizette


> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[email protected]] On
> Behalf Of Hardee, Chuck
> Sent: Tuesday, November 11, 2014 6:35 AM
> To: [email protected]
> Subject: Re: SMP/E APPLY output capture question
> 
> Thanks Christian, but I tried that already.
> I changed the utility to use the DD name ASMPRINT and then coded an
> ASMPRINT DD with SYSYOUT=* and when the APPLY was executed I received
> nothing via that DD, the usermod was not applied and I received no errors
indicating
> that there was a problem with the assembly or a problem in the APPLY.
> Very misleading.
> 
> I will, however, try it again since you have indicated that it should
work.
> It is quite possible I did not have something quite right.
> 
> I'll update again when I have further news.
> 
> C-
> 
> Charles (Chuck) Hardee
> Senior Systems Engineer/Database Administration EAS Information Technology
> 
> Thermo Fisher Scientific
> 300 Industry Drive | Pittsburgh, PA 15275 Phone +1 (724) 517-2633 | Mobile
+1
> (412) 877-2809 | FAX: +1 (412) 490-9230 [email protected] |
> www.thermofisher.com
> 
> WORLDWIDE CONFIDENTIALITY NOTE: Dissemination, distribution or copying of
> this e-mail or the information herein by anyone other than the intended
recipient, or
> an employee or agent of a system responsible for delivering the message to
the
> intended recipient, is prohibited. If you are not the intended recipient,
please inform
> the sender and delete all copies.
> 
> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[email protected]] On
> Behalf Of Christian Birr
> Sent: Tuesday, November 11, 2014 8:27 AM
> To: [email protected]
> Subject: AW: SMP/E APPLY output capture question
> 
> Chuck,
> in the SMP/E dialog select the global zone, under UTILITY select ASMA90
(or what
> else you might use), specify a print DD name and use this in your JCL and
review
> the PARM statements.
> Christian
> -----Ursprüngliche Nachricht-----
> Von: IBM Mainframe Discussion List [mailto:[email protected]] Im
> Auftrag von Hardee, Chuck
> Gesendet: Dienstag, 11. November 2014 13:54
> An: [email protected]
> Betreff: SMP/E APPLY output capture question
> 
> Hello Listers,
> 
> I am in need of capturing the output from an APPLY step, specifically the
assembly
> and link output.
> Currently my target zone has SYSPRINT defined as SYSOUT=*.
> I have tried several things but, unless I've coded them incorrectly, they
did not
> achieve the result I need.
> 
> I have tried supplying a defining a OUTPUT statement at the start of my
job and
> then supplying a SYSPRINT DD with an OUTPUT= naming the OUTPUT
> statement's name. That didn't work, and I didn't get any indication from
SMP/E as to
> errors, but my usermod was not applied.
> 
> I have tried defining the assembler utility as using an alternate SYSPRINT
DD and
> then supplying that DD and I don't get the assembly output via the new DD
name
> which I supplied in the JCL. In fact, I don't get any errors with that
setup either but
> the usermod did not apply in the arrangement either.
> 
> Ultimately, what I want to accomplish it to have 2 copies of the output.
One to go to
> our production control department as part of the documentation filed when
locking
> down the source and the other to stay within our own library system so
that if we
> have issues with the program being controlled, we have quicker and easier
access
> to the current listing than we would if we had to go thru the production
control library.
> 
> I can obtain the result I want, to a degree, if I manually change the
output class,
> form and destination as we have JES writers to handle it, but I'd rather
not have to
> remember to go and change the various JES attributes of the job if I can
do it in the
> JCL.
> 
> If there is some way to cause SMP/E to spool its assembly and link steps
to VIO
> that would be great as I could then follow the APPLY step with an IEBGENER
and
> code SYSUT2 with the appropriate OUTPUT names and have the output handled
> as I want.
> 
> Anyone have any ideas?
> 
> Thanks,
> Chuck
> 
> Charles (Chuck) Hardee
> Senior Systems Engineer/Database Administration EAS Information Technology
> 
> Thermo Fisher Scientific
> 300 Industry Drive | Pittsburgh, PA 15275 Phone +1 (724) 517-2633 | Mobile
+1
> (412) 877-2809 | FAX: +1 (412) 490-9230 [email protected] |
> www.thermofisher.com
MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to