See if the /*OUTPUT Jcl statement could help. Lizette
> -----Original Message----- > From: IBM Mainframe Discussion List [mailto:[email protected]] On > Behalf Of Hardee, Chuck > Sent: Tuesday, November 11, 2014 6:35 AM > To: [email protected] > Subject: Re: SMP/E APPLY output capture question > > Thanks Christian, but I tried that already. > I changed the utility to use the DD name ASMPRINT and then coded an > ASMPRINT DD with SYSYOUT=* and when the APPLY was executed I received > nothing via that DD, the usermod was not applied and I received no errors indicating > that there was a problem with the assembly or a problem in the APPLY. > Very misleading. > > I will, however, try it again since you have indicated that it should work. > It is quite possible I did not have something quite right. > > I'll update again when I have further news. > > C- > > Charles (Chuck) Hardee > Senior Systems Engineer/Database Administration EAS Information Technology > > Thermo Fisher Scientific > 300 Industry Drive | Pittsburgh, PA 15275 Phone +1 (724) 517-2633 | Mobile +1 > (412) 877-2809 | FAX: +1 (412) 490-9230 [email protected] | > www.thermofisher.com > > WORLDWIDE CONFIDENTIALITY NOTE: Dissemination, distribution or copying of > this e-mail or the information herein by anyone other than the intended recipient, or > an employee or agent of a system responsible for delivering the message to the > intended recipient, is prohibited. If you are not the intended recipient, please inform > the sender and delete all copies. > > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:[email protected]] On > Behalf Of Christian Birr > Sent: Tuesday, November 11, 2014 8:27 AM > To: [email protected] > Subject: AW: SMP/E APPLY output capture question > > Chuck, > in the SMP/E dialog select the global zone, under UTILITY select ASMA90 (or what > else you might use), specify a print DD name and use this in your JCL and review > the PARM statements. > Christian > -----Ursprüngliche Nachricht----- > Von: IBM Mainframe Discussion List [mailto:[email protected]] Im > Auftrag von Hardee, Chuck > Gesendet: Dienstag, 11. November 2014 13:54 > An: [email protected] > Betreff: SMP/E APPLY output capture question > > Hello Listers, > > I am in need of capturing the output from an APPLY step, specifically the assembly > and link output. > Currently my target zone has SYSPRINT defined as SYSOUT=*. > I have tried several things but, unless I've coded them incorrectly, they did not > achieve the result I need. > > I have tried supplying a defining a OUTPUT statement at the start of my job and > then supplying a SYSPRINT DD with an OUTPUT= naming the OUTPUT > statement's name. That didn't work, and I didn't get any indication from SMP/E as to > errors, but my usermod was not applied. > > I have tried defining the assembler utility as using an alternate SYSPRINT DD and > then supplying that DD and I don't get the assembly output via the new DD name > which I supplied in the JCL. In fact, I don't get any errors with that setup either but > the usermod did not apply in the arrangement either. > > Ultimately, what I want to accomplish it to have 2 copies of the output. One to go to > our production control department as part of the documentation filed when locking > down the source and the other to stay within our own library system so that if we > have issues with the program being controlled, we have quicker and easier access > to the current listing than we would if we had to go thru the production control library. > > I can obtain the result I want, to a degree, if I manually change the output class, > form and destination as we have JES writers to handle it, but I'd rather not have to > remember to go and change the various JES attributes of the job if I can do it in the > JCL. > > If there is some way to cause SMP/E to spool its assembly and link steps to VIO > that would be great as I could then follow the APPLY step with an IEBGENER and > code SYSUT2 with the appropriate OUTPUT names and have the output handled > as I want. > > Anyone have any ideas? > > Thanks, > Chuck > > Charles (Chuck) Hardee > Senior Systems Engineer/Database Administration EAS Information Technology > > Thermo Fisher Scientific > 300 Industry Drive | Pittsburgh, PA 15275 Phone +1 (724) 517-2633 | Mobile +1 > (412) 877-2809 | FAX: +1 (412) 490-9230 [email protected] | > www.thermofisher.com MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN