Until Bob Shannon recounted his experience with failed DASD (!), I would 
have looked for a more likely explanation. Here's my first take. IODF gets 
dynamically activated over a period of time. Depending on how rigorous you 
are, the IOCDS in the SE may get updated less often. It's possible for the 
actual system configuration to stray quite far from the IOCDS that was 
last written out. After a power failure, you necessarily do a POR that 
reads the IOCDS. If the last saved IOCDS cannot map the actual physical 
configuration, very strange results can occur during IPL. 

I have little experience with z/VM, so my guess might be way off base. 

.
.
J.O.Skip Robinson
Southern California Edison Company
Electric Dragon Team Paddler 
SHARE MVS Program Co-Manager
626-302-7535 Office
323-715-0595 Mobile
[email protected]



From:   Karl Severson <[email protected]>
To:     [email protected], 
Date:   05/07/2014 03:07 PM
Subject:        Re: z10 IPL from Utility Tape
Sent by:        IBM Mainframe Discussion List <[email protected]>



>OOPS, my bad. I should have realized from the VOLSERs that it was z/VM.

BTW - I, personally, _never_ IPL via an activation profile. I just use the
"LOAD" function on the "Recovery" page. I drag the LPAR icon onto the LOAD
icon. This gives me a "pop up" in which I can put the IPL volume and LOAD
parameters (it remembers what I put in last time, however, and initializes
the popup with those values).

I don't know if trying the above would give you a better message than 
using
the activation profile. But, hey, you're down, so it can't really hurt to
try, right?
<
No worries. We have the HMC set up tree style but next time I'm out there 
I might change it to classic and try it the way you do it. 

It seems now that the primary SE is saying that there are "one or more 
objects in an unexceptable state" so I'll have to find out what they are. 
Could be the root of all our problems right there.