Hello Group, I was getting the below error while allocating ZFS, I understand that VSAM has a limit of 4GB and the below allocation is more than 4GB. We have not defined a DATACLAS to honour allocation more than 4GB. Is there a other way to allocate >4G of VSAM without having a dataclas ?
IDCAMS SYSTEM SERVICES TIME: 3 04/16/14 PAGE 1 DEFINE CL - (NAME(CHRIS.DB2.LOG) LIN SHR(3,3) - CYL(8000 1000) - STORCLAS(SCSTOR) - ) IGD01010I ALLOCATION SET TO SGSTOR STORAGE GROUP IGD17103I CATALOG ERROR WHILE DEFINING VSAM DATA SET CHRIS.DB2.LOG RETURN CODE IS 140 REASON CODE IS 110 IGG0CLEV IGD306I UNEXPECTED ERROR DURING IGG0CLEV PROCESSING RETURN CODE 140 REASON CODE 110 THE MODULE THAT DETECTED THE ERROR IS IGDVTSCU SMS MODULE TRACE BACK - VTSCU VTSCT VTSCH VTSCG VTSCD VTSCC VTSCR SSIRT SYMPTOM RECORD CREATED, PROBLEM ID IS IGD00475 IGD17219I UNABLE TO CONTINUE DEFINE OF DATA SET CHRIS.DB2.LOG IDC3014I CATALOG ERROR IDC3009I ** VSAM CATALOG RETURN CODE IS 140 - REASON CODE IS IDC3009I IGG0CLEV-110 IDC3003I FUNCTION TERMINATED. CONDITION CODE IS 12 IDC0002I IDCAMS PROCESSING COMPLETE. MAXIMUM CONDITION CODE WAS 12 *** Chris ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN