Peter (et al):

I have only one comment in regards to your thoughts (below).  when you say 
projects to move off the mainframe have a high rate of failure, it depends on 
how it is done.  One of the vendors I work with has superior success rates in 
regards to conversion/migration from a mainframe to an LUW environment.

Regards,

Mitch



-----Original Message-----
From: Farley, Peter x23353 <[email protected]>
To: IBM-MAIN <[email protected]>
Sent: Mon, Jan 6, 2014 2:51 pm
Subject: Re: Innovating an old IMS 3270-based application


As usual, it depends on how far forward the original "monster application' 
esigners looked (or not...).  If the core business logic is separated from the 
presentation layer" (i.e., if the business logic is well separated from the 
270 screen processing logic), it might be possible to directly re-engineer it 
ith an HTML layer in place of the 3270 layer.
If the screen-handling and the business logic are tightly woven together, not 
so 
asy at all.
I have no experience at all with IMS applications, much less with interfacing 
hem to web browsers, but if the "business function" is well separated from the 
user interaction" parts, it should be possible.
Such projects are never easy, though.  Sometimes, unfortunately, the best 
ecision (financially and time-wise) is to start over from scratch.  For a staff 
ith limited z/OS skills, that could result in a project to move completely off 
f z/OS.  Those kinds of projects have a very high rate of failure.
One other possibility is the use of one of the several "3270-to-browser" 
onversion products I think are out there, which (if I understand the functions 
rovided) take your 3270 screen inputs and outputs and convert them back and 
orth in a web browser.  Not pretty, and almost certainly affects round-trip 
ime from "enter" to results screen, but supposedly quite functional.
All I can say is good luck.  You're going to need it.
Peter
-----Original Message-----
rom: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
f Sanya Off
ent: Monday, January 06, 2014 4:56 PM
o: [email protected]
ubject: Innovating an old IMS 3270-based application
Folks,
I wonder if some of you may share the experience and opinions with regards
o approaching a grand task of making an old IMS-based monster application
ore friendlier to users and developers:
- users want web-based access;
- developers are limited in their skills (particularly, z/OS skills)
Specifically, I think of using MQ to intercept/separate 3270-bound flow...
ny advice?
I'd be grateful...
A.I.
----------------------------------------------------------------------
or IBM-MAIN subscribe / signoff / archive access instructions,
end email to [email protected] with the message: INFO IBM-MAIN
This message and any attachments are intended only for the use of the addressee 
nd may contain information that is privileged and confidential. If the reader 
f the message is not the intended recipient or an authorized representative of 
he intended recipient, you are hereby notified that any dissemination of this 
ommunication is strictly prohibited. If you have received this communication in 
rror, please notify us immediately by e-mail and delete the message and any 
ttachments from your system.
----------------------------------------------------------------------
or IBM-MAIN subscribe / signoff / archive access instructions,
end email to [email protected] with the message: INFO IBM-MAIN


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to