Make sure your PLEXCFG in IEASYSxx is appropriate. We have PLEXCFG=ANY. On Thu, Aug 14, 2025 at 1:13 AM Peter < [email protected]> wrote:
> Hello > > I am testing the newly installed zos 3.1 and while doing the first IPL I > get the below message > > This environment is a monoplex and not sure why the below response is not > accepted . > > Any pointers would be appreciated > > IEE600I REPLY TO 00 IS;COUPLE=** > > 2025226 10.02.09 XXX IXC470I SYSTEM ROPB EFFECTIVE VALUES: INTERVAL=165 > OPNOTIFY=168 > > DEFAULT USER INTERVAL: 165 > > DERIVED SPIN INTERVAL: 165 > > DEFAULT USER OPNOTIFY: + 3 > > COMPUTED FOR: XCF INITIALIZATION > > 2025226 10.02.09 XXXX IXC412I SYSPLEX CONFIGURATION IS NOT COMPATIBLE WITH > REQUIRED CONFIGURATION > > 2025226 10.02.09 XXXX IXC413I MULTISYSTEM SYSPLEX CONFIGURATION PREVENTED > BY PLEXCFG=MONOPLEX > > 2025226 10.02.09 XXXX IXC413I XCFLOCAL SYSPLEX CONFIGURATION PREVENTED BY > PLEXCFG=MONOPLEX > > 2025226 10.02.09 XXXX IXC241I UNABLE TO PROCESS "COUPLE=**" SPECIFICATION > BECAUSE THE PLEXCFG SPECIFICATION PREVENTED XCF-LOCAL MODE > > 2025226 10.02.09 XXXX IXC240I IF XCF-LOCAL MODE INITIALIZATION IS DESIRED, > RE-IPL WITH "PLEXCFG=XCFLOCAL" AND "COUPLE=**" > > 2025226 10.02.09 XXXX * IXC207A XCF INITIALIZATION IS RESTARTED. RESPECIFY > COUPLE SYSTEM PARAMETER, REPLY COUPLE=XX. > > > > Peter > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to [email protected] with the message: INFO IBM-MAIN > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN