Hello I am testing the newly installed zos 3.1 and while doing the first IPL I get the below message
This environment is a monoplex and not sure why the below response is not accepted . Any pointers would be appreciated IEE600I REPLY TO 00 IS;COUPLE=** 2025226 10.02.09 XXX IXC470I SYSTEM ROPB EFFECTIVE VALUES: INTERVAL=165 OPNOTIFY=168 DEFAULT USER INTERVAL: 165 DERIVED SPIN INTERVAL: 165 DEFAULT USER OPNOTIFY: + 3 COMPUTED FOR: XCF INITIALIZATION 2025226 10.02.09 XXXX IXC412I SYSPLEX CONFIGURATION IS NOT COMPATIBLE WITH REQUIRED CONFIGURATION 2025226 10.02.09 XXXX IXC413I MULTISYSTEM SYSPLEX CONFIGURATION PREVENTED BY PLEXCFG=MONOPLEX 2025226 10.02.09 XXXX IXC413I XCFLOCAL SYSPLEX CONFIGURATION PREVENTED BY PLEXCFG=MONOPLEX 2025226 10.02.09 XXXX IXC241I UNABLE TO PROCESS "COUPLE=**" SPECIFICATION BECAUSE THE PLEXCFG SPECIFICATION PREVENTED XCF-LOCAL MODE 2025226 10.02.09 XXXX IXC240I IF XCF-LOCAL MODE INITIALIZATION IS DESIRED, RE-IPL WITH "PLEXCFG=XCFLOCAL" AND "COUPLE=**" 2025226 10.02.09 XXXX * IXC207A XCF INITIALIZATION IS RESTARTED. RESPECIFY COUPLE SYSTEM PARAMETER, REPLY COUPLE=XX. Peter ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN