Hi Richard,
Assuming that your "console" uses software emulation (e.g. PCOMM), you
could code a "Screen Scraper" to "see" messages and take action.
Regards,
David
On 2023-03-16 09:01, Richard McIntosh wrote:
Is there anyway to get alerted to a linklist error duing the IPL process. The
error messages come out to early for any MPF processing to hilite it and they
rolled by to quick for operations to notice and caused TLMS to not get
initialized. Dataset is not in master catalog and the wrong volser was
specified.
IGGN307I SYSP01,SYSR.TLMS.R14MA.CTAPLINK,DATA SET NOT FOUND ON VOLUME
IEA716I UNABLE TO OPEN LIBRARY - LNKLST DATA SET IGNORED
SYSR.TLMS.R14MA.CTAPLINK
I googled an old (18 years ago) message about someone using the IEAVMXIT exit
to check some storage to see if any error flags were set, but there was no
mention of what storage it was.
Thanks
Richard McIntosh
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN