I am have no experience using zIIPs but if an operator can offline one, so can 
NetView using the BCPii ProcOPs interface. Your batch step could issue a WTO 
that triggers an appropriate NetView Rexx script. Assuming you have NetView, of 
course. :)

HTH
-Robin

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of Rob Scott
Sent: 23 August 2012 16:25
To: [email protected]
Subject: Re: disable zIIP usage for the remaining part of one Job

The interface to control a program usage of zIIPs is a licensed feature that 
ISVs will build into their products - it is not something that is exposed to 
"normal" customers.

If you wish to disable zIIP processing for a specific program step, your only 
options as I see it are :

(1) Contact the vendor of the program to see if they have any runtime options 
to disable the zIIP usage by their code

Or

(2) Put a "wait on WTOR" jobstep in the JCL before the program jobstep and then 
manually vary the zIIP processor offline before replying to the WTOR.


Option (2) is obvious overkill - however it might be possible on a 
non-production system without too many complaints :-)  


Rob Scott
Lead Developer
Rocket Software
77 Fourth Avenue . Suite 100 . Waltham . MA 02451-1468 . USA
Tel: +1.781.684.2305
Email: [email protected]
Web: www.rocketsoftware.com

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of Monika Amiss
Sent: 23 August 2012 07:56
To: [email protected]
Subject: disable zIIP usage for the remaining part of one Job

Dear Group,

 do I have a chance to disable zIIP-usage during a job run by calling an 
Assembler program which does the disable. The disable should be only for this 
STEP.

  Any hint appreciated, with best regards Monika 

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN This message has been 
scanned by MailController - portal1.mailcontroller.co.uk

----------------------------------------------------------------------