Did you remember to use REUSASID=YES on the start command for the STC that owns 
the system-LX ?

Rob Scott
Lead Developer
Rocket Software
77 Fourth Avenue . Suite 100 . Waltham . MA 02451-1468 . USA
Tel: +1.781.684.2305
Email: [email protected]
Web: www.rocketsoftware.com

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of Micheal Butz
Sent: 18 June 2012 03:26
To: [email protected]
Subject: IEF352I ADDRESS SPACE UNAVAILABLE

HI,

 

 I have a PC rtn for which I reserve a system entry

 

 

  LXRES ELXLIST=EX_LIST,  

       SYSTEM=YES,       

       REUSABLE=YES,     

       MF=(E,LXRES_DSECT)

 

 

Later when  I clean things up

 

  LXFRE ELXLIST=EX_LIST,FORCE=YES,MF=(E,LXFRE_DSECT)

 

I free the linkage entry and get a zero in R15

 

However I still get

 

IEF352I ADDRESS SPACE UNAVAILABLE

 

Thankx in advance   


----------------------------------------------------------------------